DOW-UAP-D130 — AAWSAP DIRD, Technological Approaches to Controlling External Devices, March 2010
File DOW-UAP-D130 is a declassified pdf from Department of War, recording an incident dated 3/23/10 at Las Vegas, Nevada, published in Release 06 (2026-09-18). This page carries the original file, its official summary and its full text.
- File
- DOW-UAP-D130
- Agency
- Department of War
- Incident date
- 3/23/10
- Location
- Las Vegas, Nevada
- Released in
- Release 06 (2026-09-18)
- File type
Topics: AAWSAP & DIRDs
This document is a Defense Intelligence Reference Document (DIRD), a technical reference format used by the Defense Intelligence Agency (DIA) to capture baseline knowledge on a specific topic for later analytic use. DIRDs are best understood as reference and synthesis products rather than as original research. It is one of 38 DIRDs produced under the Advanced Aerospace Weapon System Applications Program (AAWSAP) between 2009 and 2011. Because AAWSAP’s scope permitted a broad range of supporting topics, not every DIRD in the series directly concerns aerospace systems or future threat assessment. The following summary reflects the DIRD’s scope and framing at the time of writing and should not be read as implying current validation of the concepts discussed.
This DIRD surveys brain-machine interface technologies intended to allow users to control external devices without conventional manual controls, and it evaluates both noninvasive and invasive approaches for turning neural or related physiological signals into usable commands. The report reviews the underlying neural signals, distinguishes between open- and closed-loop control systems, and examines technologies including scalp-based electrical recording, magnetic and imaging-based methods, and implanted cortical interfaces, with particular attention to bandwidth, response time, signal quality, and practical usability. It concludes that, in the near term, the most practical systems are likely to be noninvasive electrical approaches that draw heavily on muscle and neural signals, while longer-term high-bandwidth control would likely require more advanced invasive interfaces capable of robust two-way communication with individual neurons. The document presents thought-based control of external devices as a research field with plausible assistive and specialized applications, while emphasizing that naturalistic, high-performance control remained constrained by major technical and physiological limits.
Open original file · WAR.GOV page
TL;DR
They were already networking brains before Wi-Fi was a thing.
- DIRD DOW-UAP-D130, DoW, March 2010, Las Vegas, NV.
- Surveys non-invasive and invasive brain-machine interfaces, signal types, bandwidth, response time, usability.
- Concludes near-term use favors non-invasive electrical methods; long-term high-bandwidth needs invasive cortical links.
AI summary
A declassified document titled "Technological Approaches to Controlling External Devices in the Absence of Limb-Operated Interfaces," prepared by the Defense Intelligence Agency's Acquisition Support Division, dated 23 March 2010, outlines research on brain-machine interfaces, neural signals, and technologies for controlling devices without physical interaction. It covers neuronal signal transmission, brain-computer interface technologies, and various methods including EEG, MEG, EMG, MRI, fMRI, and NIRS. The document discusses input and output signal processing, closed-loop systems, noninvasive and invasive techniques, electrode designs, and experiments with nonhuman primates and human subjects. It includes technical details on neural signal recording, electrode placement, biocompatible materials, and applications for mobility restoration and device control. The text references studies from 2005 to 2009 and explores challenges and future advancements in neural interface technologies.
Full text
Page 1
UNCLASSIFIED/ /FOR OFFI
Defense
SSE - Intelligence
DEEEE 4
Reference
ES OF Document
Acquisition Threat Support
23 March 2010
ICOD: 1 December 2009
DIA-08-1003-012
Technological Approaches to
Controlling External Devices in
the Absence of Limb-Operated
Interfaces
UNCLASSIFIED/ /FOR- ONLX
Page 2
UNCLASSIFIED//F8R 8FFl6i,t.k Miili Ot!P X
Technological Approaches to Controlling External Devices
in the Absence of Limb-Operated Interfaces
Prepared by:
Acquisition Support Division (DW0-3)
Defense Warning Office
D irectorate for Analysis
Defense Intelligence Agency
Author:
AAP Person 73
Administrative Note
COPYRIGHT WARN ING: Further dissemination of the photographs in this publication is not authorized.
This product is one in a series of advanced technology reports produced in FY 2009
under the Defense Intelligence Agency, Defense Warning Office's Advanced Aerospace
Weapon System Applications (AAWSA) Program. Comments or questions pertaining to
this document should be addressed to !AAP Person 1
l AAWSA Program
Manager, Defense Intelligence Agency, ATTN: CLAR/DWO-3, Bldg 6000, Washington,
DC 20340-5100.
ii
UNCLASSIFIED/ /FQA &FFIGIAk Wiili ,u11a¥
Page 3
UNCLASSIFIED/ /FOlil OFFI&I.t.k WIiii 8Plklf
Contents
Introduction ............................................................................................................v
Direct Neural Signals.............................................................................................. 1
Indirect Neuronal Signals - The BOLD Effect.......................................................... 3
Control of External Devices .................................................................................... 4
Noninvasive Technologies ...................................................................................... 6
EEG ..................................................................................................................... 7
MEG .................................................................................................................... 8
EMG .................................................................................................................... 9
MRI and fMRI ..................................................................................................... 9
NIRS .................................................................................................................... 10
Invasive Technologies .......................................................................................... 10
Open-Loop Direct Cortical Array Algorithm Modeling ....................................... 11
Closed-Loop Peripheral Arrays Utilizing Visual Feedback ................................. 13
MEMS, ECoG, and PSoC Circuitry ...................................................................... 14
Chronic Neural Implants and fMRI ................................................................... 16
New Electrode Designs ..................................................................................... 18
Hybrid Neuro-Robotic Systems for True Closed-Loop BMI ................................ 20
Trials Using Human Subjects ............................................................................ 22
Optical Stimulation of Action Potentials ........................................................... 23
Discussion ............................................................................................................ 23
Noninvasive Electrical Devices ......................................................................... 24
Noninvasive BOLD-Based devices..................................................................... 25
Noninvasive Magnetic Devices ......................................................................... 26
Invasive Technologies - General, Optical, and Ex-Vivo Engineering ................. 26
Implantable Chips, Ladders, and Arrays ........................................................... 27
iii
UNCLASSIFIED/ /rOR: orr1e1J1ct U91!! OHL¥
Page 4
UNCLASSIFIED/ ,'FOR: 8ffl@IJllt t:191!! l>flt I
Conclusions .......................................................................................................... 27
Figures
Figure 1. Simplified Rendering of a Neuron ............................................................ 1
Figure 2. The General Layout of a Closed-Loop Control Interface ........................... 5
Figure 3. Two Commercially Available EEG Sensors................................................ 8
Figure 4. Experimental Overview of Brain-Controlled Robot in a Closed Loop
With Visual Feedback Experiment ......................................................... 13
Figure s. Schematic of the Neurochip Functional Blocks ...................................... 15
Figure 6. Implant Location ................................................................................... 16
Figure 7. Histology and Electrode Tracks ............................................................. 17
Figure 8. The Michigan Electrodes ........................................................................ 18
Figure 9. Image Distortion and Custom Microwire Electrode Assembly to
Improve It ............................................................................................. 19
Figure 10. Example of T2 Variability ..................................................................... 19
Figure 11. T2 Value Analysis Summary of T2 Values in All the Image Slices That
Spanned the Electrode Arrays in All Animals ....................................... 20
Figure 12. A Hybrid Neuro-Robotic System .......................................................... 21
Figure 13. Experimental Arrangements ................................................................ 21
iv
UNCLASSIFIED/ /FOil Offl@IJllL YSIE 8Htlf
Page 5
UNCLASSIFIED/ /P(Ht err1e1s1tt l!ISI!!! 9HL'I
Technological Approaches to Controlling External Devices
in the Absence of Limb-Operated Interfaces
Introduction
Since the advent of modern interactive control of computers, technologies
have been sought to directly connect the biological and the physical to form a
seamless entity. While science fiction explores the possibilities of shared
consciousness between brains and mainframes, real-life scientists work
toward an equally fantastic but more pedestrian goal of eliminating required
electromechanical human-machine interfaces (HMis). Such technologies
promise integration of thought and computer-controlled action, without the
need for a limb-operated device to translate intent from physiological
networks to physical circuits.
This paper first briefly reviews underlying neural structure, function, and
activity to provide background on the type of signals and the scale of temporal
changes that arise from conscious control within the nervous system. A short
primer on brain-machine interfaces (BMis) is included at the end of the
background material. This is followed by a survey of the state-of-the-art
detection and stimulation technologies available utilizing noninvasive and
invasive methods, including several studies that exemplify research paths
currently being undertaken. Discussion brings together elements of the
technology survey, application limitations, a timeline for useful commercial
deployment, and predicted future research directions. Two technology
research paths are highlighted as the most probable to produce functionally
useful devices (defined as nearly equal or even superior to the control
capabilities of current HMis) in the near and far term.
The technology endpoint this paper seeks is thought-based operation of
remote machinery during normal human activities without mechanical device
interaction-that is, control of external devices without the need to go to a
specified location, such as a shielded room; without the need to remain
perfectly motionless to reduce signal noise; and without the need for
interaction with a normal electro-mechanical device, such as an i-Phone or
other handheld device with buttons and trackballs. Data transfer rates are
sought to exceed 5-10 bits/second to be useful for operation of complex
devices; this rate range and above is referred to as high-bandwidth BMis.
Response time for a 1-of-N selection of commands is targeted at 300
milliseconds or less. These are the operational parameters assumed for final
implementation unless some limitation or supercapability is described.
The paper concludes that noninvasive electrical monitoring of neural activity,
primarily reading combined action of muscles and neurons, is the most
promising commercial technology in the near term. Inherent limitations in the
noninvasive electrical approach require future development of different
research paths. The paper argues, mainly by eliminating other approaches,
that the most probable technology in the long term involves invasive single
neuron-based direct cortical connections to form a network of high-bandwidth
duplex communication pathways. Currently the most promising technologies
V
UNCLASSIFIED/ /FOR. OFFIGIAk Uii QPlk¥
Page 6
UNCLASSIFIED/ /P91t 9Ffl@IAL YSIE 8HLY
for robust construction of such an interface are optical stimulation, gating, and
sensory devices, and chip-based electrode arrays that have been encased in
ex-vivo-engineered neural tissue.
vi
UNCLASSIFIED/ /FOR. orrlEIAL U.!~ Gilt I
Page 7
UNCLASSIFIED/ /POR: err1e1At l:191!! er•t I
Direct Neural Signals
The human nervous system has two classes of cells, neurons and glia. Based on all
research to date, it is believed that signals within the network of neurons constitute the
whole of information processing, with gl ial cells playing a purely supporting role. This
neural doctrine has dominated research in BMI until recently and still constitutes the
only major research path in direct technologies. Furthermore, all technologies directly
measuring human neuronal action rely on detecting or influencing electrical activity of
these cells; no current in situ research selectively affects neurotransmitter activity
between local cells for the purpose of information exchange . Therefore, the focus for
the foreseeable future will be on the electrical activity of neurons as the primary target
of BMI.
Neurons consist of four parts: axon, dendrites, cell body or soma, and pre-synaptic
terminals. Electrical information is transmitted to the neuron through the dendrites,
proceeds through the cell body, and leaves the cell through the axon at one or more
pre-synaptic terminals. Neurons have one axon and from one to tens of thousands of
dendrites.
Figure 1. Simplified Rendering of a Neuron. The arrows indicate t he direction in which signals are
conveyed . The single axon conducts signals away from the cell body, while the multiple dendrites receive
signals from the axons of other neurons. The nerve terminals end on the dendrites or cell body of other
neurons or on other cell types, such as muscle or gland cells. (Reference 1)
Chemical details of how the action potentials travel through the cell or are transmitted
across the synapse are not important to the current treatise, other than the distinction
that in these biologically based electrical networks, ions of sodium, potassium, and
chlorine move through the cell membranes perpendicular to the propagation of the
action potential down the axon. This allows information to be transmitted faster than
ions could flow down the axon. The propagation of information is sim il ar to a wave
traveling down a garden hose: quickly move one end of the hose back and forth with
sufficient force, and a wave will travel to the other end of the hose; however, any part
of the hose structure has only moved (nominally) perpendicular to the direction of wave
propagation. In a similar fashion, ions flow through channels across the axon's cell
membrane, changing the local membrane potential and thus propagating the electrical
signal down the axon.
1
UNCLASSIFIED/ ;'FOR OFFI&I.t.k Wliliii 8fslk¥
Page 8
UNCLASSIFIED/ ;'FOR OFFl&I.t.k Wliliii &NL¥
The signal transmission down the axon of a neuron is an all-or-nothing process. When
the cell body is stimulated above threshold, the axon transmits the same action
potential at the same speed and in the same direction, regardless of the extent above
threshold or duration of the input. Action potentials have durations of 1-10
milliseconds. Input signals can result in transmission of multiple action potentials, and
thus the frequency and number of neuronal firings do vary with the input. Neurons
require some t ime to reset between firings, nominally the duration of the pulse for that
axon, yielding a typical maximum firing rate of between 100 hertz (Hz) and 1 kilohertz
(kHz).
It is instructional at this point to contrast this mechanism with propagation of signals
through a physical electrical circuit, the planned external portion of our BMI. In a
copper wire, electrons carry the signal. Electrons drift along the signal path, but the
signal itself moves as a compression wave rather than a transverse wave as in the
biologica l system. Going back to our garden hose example, consider the hose now filled
with small marbles: inserting a marble at one end will move each marble in the hose
just a little, but very rapidly the last marble in line will pop out of the far end of the
hose. As with the biological system, the signal is propagated to the far end of the hose
by local actors rather than physical motion of a single ion or electron moving the whole
distance. The underlying physics governing the signal transmission makes metallic and
semimetallic circuits about a million times faster than the biological system.
This difference in the carriers and underlying mechanisms of signa l transmission
between biological and physical circuits has so far prevented the invention of a direct
connection between the two disparate systems. Instead, both noninvasive and invasive
direct-detection technologies rely on placing physical sensors or transmitters in close
proximity to the neurons of interest and utilizing classical electrodynamics to govern
signal jump between the systems. Additionally, given the maximum typical firing rate
for neurons of 1 kHz, sampling of action potentials at a few kHz will be fast enough to
detect firing of any individual neuron, though super-sampling above 10 kHz can be used
to reduce noise. Higher sampl ing frequencies also may be required if multiple neurons
are monitored and quantitative information about their relative firing sequence is
desired . Frequencies of a 1 kHz or below are sufficient to stimulate action potentials,
and again, higher system frequency may be required for multiple neuron sequential
stimulation. Finally, higher frequencies may be required if monitoring or stimulation of
some aspect of signal transmission other than action potentials is sought, such as
monitoring single ion channels. 1 There is currently no evidence that transduction
frequencies above 100 kHz have any advantage in BMis, thus the main challenge is the
connection dynamics, since even this ultra-maximum frequency is easily attainable with
current electronic manufacturing technology.
The human brain doesn't process information as a traditional computer does.
Information is moved around through pathways and at certain neurons it is allowed or
not allowed to pass based on excitory or inhibitory dendritic signals arriving before
triggering of action potentials . Local groups of neurons can act nearly coherently, for
example in volition of motor action like a hand movement. Detecting such coherent
firing at nodes around the bra in is robust both noninvasively and invasively, though
1 Technologies that monitor single ion channels on a neuronal membrane are important for researc h on
neural
function and neurotransm itter action . However, these devices are ultra -sensitive to physical motion, and have so
far not proven useful in large scale information transfer required in BMis .
2
UNCLASSIFIED/ /fOll OFFl@IAl W&lii OPU..¥
Page 9
UNCLASSIFIED/ /FOR OFFl&IAk le.ISi: OPtklf
noninvasive techniques currently cannot resolve firing sequences of individual neurons
within such groups.
Living neurons in an active tissue fire in the rest state. Changes in the frequency of
these firings imply that a given neuron is currently involved in the processing of
information. Bulk changes in local field potential oscillations imply that several neurons
are active. This is the signal seen in the noninvasive direct-measurement techniques of
electroencephalography (EEG) and magnetoencephalography (MEG).
Movement as simple as an eye blink involves signal communication through a million
neurons. Several locales in the nervous system thus offer the possibility of placement of
an invasive monitoring device for detecting electrical activity associated with an eye
blink or other signal of interest. Many other factors will influence the placement
decision, but considering only catching the signal as an action potential, using any
neuron along the complete pathway is equally as good, assuming detection of individual
neuronal firing can be accomplished.
Considering cortical placement of detection devices, the most common area of activity
under study is the outer covering of gray matter of the cerebral cortex, the neocortex.
The neocortex is about 2. 5 mm thick in humans and follows the ridges and fissures of
the brain (gyri and sucli, respectively, or gyrus and sulcus, if singular). The neocortex is
roughly divided into six layers and different cortical probes can concentrate on activity
in different layers, or just measure the combined activity on the surface of the cortex,
or the combined activity that is detectable noninvasively through the layers of tissue
and bone of the cranium.
Detecting single firings of individual neurons is a difficult process because the signals
are weak to start with, and not isolated from the rest of the electrical activity within the
brain. Large groups of coherent neurons, perhaps a few thousand to tens of thousands
all firing at once in relation to an external event, are the most studied of single firing
signals. 2 One of the most studied signals is the so-called P300 which occurs in many
cognitive tasks (References 2-4).
P300 is a term used to indicate a pulse signal from a large group of neurons that
appears about 300 milliseconds after a stimulus event. Peaks that occur between 200
and 400 milliseconds are commonly grouped into the P300 category. The "P" stands for
a positive measured voltage, while "N" signals are negative. 3 The P300 signal has been
shown to be influenced by top-down executive function and is therefore a prime
candidate for a trainable interface (Reference 5). Earlier signals, like PS0 and Nl00, are
of a greater interest for differential diagnosis of pathology in current research.
The preceding discussion is greatly simplified version of the electrical dynamics of
neuronal firing and does not include differences between axon and dendrite signals, or
the transmission of signals across the synapse. Complete discussion of underlying
electrical signals in the nervous system can be found in (References 6, 7).
Indirect Neuronal Signals - The BOLD Effect
2 Single firing signa ls here mean a single peak of combined electrical activ ity relative to an event. This is not
necessarily the same as single firings of each neuron .
3 The literature is not consistent with plotting P signals up, and N signals down ; however, P peaks are always in the
opposite direction of N peaks.
3
UNCLASSIFIED/ /POil OPPl@IAL liSI!! 8HLY
Page 10
UNCLASSIFIED/ /EOR OlifilEIAk W&li (UtLY
The brain activity mentioned above is a complex chain of ionic motion within the central
nervous system. Ionic production, release, and movement within and between cells all
consume energy. This energy is supplied by the conversion of blood-borne
oxyhemoglobin to deoxyhemoglobin. The rate of oxygen consumption in a localized
volume varies based on local neural activity. The circulatory system compensates for
changes in energy demand by increasing or decreasing both the flow rate and volume
of blood, regionally and locally. Local energy demand, expressed in the capillary beds,
will alter the rate at which oxygen is metabolized, called the cerebral rate of oxygen
metabolism, abbreviated CMRO2. When brai n activity increases in a region, the
circulatory response, called the hemodynamic response, will be increases in flow and
volume, while the local areas increase CMRO2.
The hemodynamic response consistently provides an excess of oxygen over what is
required, and this results in some oxyhemoglobin traveling through the capillary bed
and local venous structure without being converted into deoxyhemoglobin. Oxy- and
deoxyhemoglobin have different magnetic susceptibilities, and different infrared
spectra. The hemodynamic response, by changing the net ratio of oxy- to
deoxyhemoglobin in the local venous structure, thus changes the local magnetic
susceptibility and local infrared resonance spectra around focused brain activity. This
complex chain reaction is called the Blood Oxygen Level Dependent, or BOLD effect
(Reference 8). The BOLD effect leads to a method to indirectly measure the local brain
activity by monitoring the hemodynamic response using Magnetic Resonance Imaging
(MRI) or Near Infrared Spectroscopy (NIRS).
The BOLD response to any event peaks about 4-6 seconds a~er the event occurs,
limiti ng the applications for which monitoring these signals and their associated delay
may be useful, given the BMI operating parameters defined above Furthermore, person
to person variation in distributed signals show significant differences in regions
activated (Reference 9), though there is evidence that these inter-subject variations are
stable intra-subject over time (Reference 10).
Control of External Devices
In general, t here are two types of BMI design called open-loop and closed-loop. Open
loop designs, those either detecting activity or providing stimulation, are important for
BMI research and application other than the practical control of an external device.
Closed-loop systems include both output signals from the brain to effect a change in the
state of a device, and a stimulation channel, which can be used as feedback. In some
system designs, the feedback can be via visual cues such as watching a display
(Reference 11). Open- loop systems are important for BMI research and have
application in sense replacement such as artificial hearing, or when extensive output
signal processing is combined with external device state feedback (see remote robot
operation below). For learning and fine, efficient control of external devices without
significant external processin g, closed-loop systems are typically needed .
Several components constitute a general BMI system for control of an external device
(Figure 2). As mentioned in the previous section, the interfaces where the information
signal makes the jump between biological and physical pathways are the most
challenging part of the system. These connections can be placed to stimulate or read
peripheral or cerebral neurons . The processing step could be as simple as amplification
4
UNCLASSIFIED/ /FOR OFFl@IAL Y!H! 8HL1/
Page 11
UNCLASSIFIED/ /FOR: 8Ffl@IJltt t:191!! er•t I
of a spiking train to trigger a switch, or as complex as decoding signal from noise
utilizing a 300-channel EEG cap.
~-------------------------,
---1 -------------------'
: Additional sensory
I
~
,----1
Brain
Output
interface
:
Input
interface
Output
signal
processing
Components of a
Closed-loop BMI
Control System
Input
signal
processing
External
Device
Figure 2. The General Layout of a Closed-Loop Control Interface. The input and output interfaces can attach
to read or affect activity of cerebra l or peripheral neurons. Add itional sensory feedback channels such as visual
displays, audio tones, or haptic feedback are possible . In some system designs, especially noninvasive types, these
sensory feedback channels replace stimulation inputs. In an open-loop interface, either the input or output signal
paths are absent.
One consideration in developing a BMI control system is the utility of the application:
does it make sense to directly tie these controls to neural activity? The bulk of research
in direct neural interfaces is toward the goal of restoring mechanical capabilities to
those individuals who have either lost limbs or lost control of limbs through central
nervous system injury or disease. In these cases it is of obvious utility to produce a
system that moves a cursor across screen to select an item over the course of several
seconds; however, for a healthy individual, it is far more practical to execute a hand
movement to control a mechanical device4 to achieve the same goal.
An exception to consider is the case of applications where the subject's hands or feet
are already occupied with other essential tasks in the overall application. A research
question for any such application is whether training a subject to uti lize a BMI is
advantageous over a more complex mechanical interface. Furthermore, whether
training on a new BMI affects learning/retaining proficiency with similar BMis is an
additional concern.
Moreover, for any BMI, one can quantitatively describe the information transfer in
controlling the magnitude of human motor action (Reference 12). Since the advent of
digital control of external devices, this information is expressed in equivalent bits per
4 Mechanical device as used here represents any limb-operated interface, such as a mouse or touchscreen.
5
UNCLASSIFIED/ /FOR OFFI&IAk W&E 8Ptk¥
Page 12
UNCLASSIFIED/ /POil 8ffl61Al W&li 0NL¥
second transferred. Higher bit rates equate to more efficient interfaces . Baseline
examples of performance include finger pointing, which can convey 14 bits/s of
information (Reference 13), operation of a mouse about 8 bits/s (Reference 14), while
stylus tapping a soft QWERTY keyboard on a PDA has a lower rate, around 5 bits/s
(Reference 15).
Once these questions are researched and answered for a given application, the design
choice should be made whether a new mechanical interface, or an optical interface that
tracking detailed motion of the eyes, body and limbs, may be the optimum solution
rather than a BMI. 5
Another consideration in developing a BMI control system is the cognitive limit of
supervisory control of external devices. The current state of the art for human
interfaces involves volition of control, meaning that there is some executive
supervision, typically involving the pre-frontal cortex, active during the control process.
Recent studies relating to control of semiautonomous vehicles show that there are
significant limits on the number of supervisory activities that can be undertaken
simultaneously (Reference 16). In response to these limits, one can consider utilization
of nonsupervised brain networks in control of external devices, similar to those brain
systems that initiate very complex muscle coordination activity such as martial arts or
playing a musical instrument, or systems like those that are responsible for autonomic
function. Application from such research is long term, but there are current studies that
show BMI training of at least one spinal cord patient exhibited differential activity in the
cerebellum, owing to extraordinary plasticity (Reference 17). It is therefore not out of
the realm of possibility that sufficient input and output interfaces that include neural
pathways through the cerebellum could result in over-learning a BMI application to the
point that supervisory control is developed and thus significant cognitive effort is not
required.
Noninvasive Technologies
There are four noninvasive technologies currently in widespread use in monitoring brain
activity. The two direct-measure technologies involve detecting surface currents from
the relative voltage changes at or just below the scalp, electroencephalography (EEG),
and detection of near scalp magnetic fields associated with neural pathway current flow,
magnetoencephalography (MEG). The remaining two indirect measures involve
monitoring BOLD response through rapid successions of whole brain MRI (functional
MRI or fMRI), and near-i nfrared spectroscopy (NIRS). 6
The primary technology used for BMI is also the oldest. EEG was first described in 1929
(Reference 18) and now exists in several derivative forms. Traditional EEG uses
electrodes at the surface of the scalp to measure and amplify potential differences
between points above the cortical surface and a fixed reference such as the average
read ing from the earlobes. Traditional EEG data is analyzed by breaking up the power
spectrum into several bands between 0.5 and 100 Hz. A derivative form of EEG
developed about 10 years later is called event-related potentials, or ERP. In ERP, scalp
5 There is a valid argument to be made that optical tracking and analysis, especially of the eyes, is a BMI
technology as defined in the current treatise. It is excluded as one merely by fiat.
6 NIRS is occasionally refe rred to as fu nctional NIRS or fNIRS. NIRS using multiple sources to produce 3D images of
internal changes in blood flow is occasionally called diffuse optical tomography (DOT) . DOT is a more genera l
technology that can also refer methods such as to visible-light laser excitation of tissue.
6
UNCLASSIFIED/ /FOil OFFl61Al WSE OHlY
Page 13
UNCLASSIFIED/ j POI\ OFFICIAL l:ISE 8Ptllf
data is averaged over several electrodes time-locked to a stimulus (Reference 19). Both
the previous methods record summed electrical activity of nominally 50,000 local
neurons, thus large coherent group spiking activity 7 is required to produce appreciable
signal.
EEG
EEG-based BMI systems use pattern recognition among the several electrodes to
transmit information. In closed-loop systems, audio or visual feedback is utilized.
Tra ining on the system and adaptation by the process ing software can increase target
Previous: DOW-UAP-D129 — AAWSAP DIRD, Metallic Spintronics, March 2010 · Next: DOW-UAP-D131 — AAWSAP DIRD, The Role of Superconductors in Gravity Research, March 2010
Same topic: title & summary match
Same location: Las Vegas, Nevada
- DOW-UAP-D174 — Utah Ranch Investigation Report, April 2010
- DOW-UAP-D166 — MUFON Reports Prepared for BAASS, November 2008
- DOW-UAP-D168 — BAASS Project Management Plan, December 2008
- DOW-UAP-D169 — BAASS Monthly Report, March 2009
- DOW-UAP-D170 — BAASS Monthly Report, April 2009
- DOW-UAP-D171 — BAASS Monthly Report, June 2009
Same period: 2010
- DOW-UAP-D114 — AAWSAP Contract Modification P00003, May 2010
- DOW-UAP-D113 — AAWSAP Contract Modification P00002, February 2010
- DOW-UAP-D115 — AAWSAP Contract Modification P00004, May 2010
- DOW-UAP-D116 — AAWSAP Contract Modification P00005, September 2010
- DOW-UAP-D133 — AAWSAP DIRD, The Space Communication Implications of Quantum Entanglement and Nonlocality, March 2010
- DOW-UAP-D134 — AAWSAP DIRD, Maverick Inventor Versus Corporate Inventor: Where Will the Next Major Innovations Arise, March 2010
Same release: Release 06
- DOW-UAP-PR159 — Historical Film of Reported UFOs, Utah, 1952
- LLE-UAP-PR001 — Unresolved UAP Report, Colorado, 2023
- LLE-UAP-PR002 — Unresolved UAP Report, Colorado, October 2023
- DOW-UAP-PR133 — Unresolved UAP Report, Middle East, 2025
- DOW-UAP-PR135 — Unresolved UAP Report, Middle East, 2025
- DOW-UAP-PR140 — Unresolved UAP Report, Middle East, 2022
Same agency: DoW
- DOW-UAP-D094 — Analysis of Flying Object Incidents in the United States, 1949
- DOW-UAP-D097 — Project Sign Progress Report, 1948
- DOW-UAP-D084 — US Army-Flying-Saucer-Study 1949
- DOW-UAP-D155 — Air Intelligence Information Report, Saudi Arabia, 1957
- DOW-UAP-D176 — Triangular UAP AARO Memorandum for Record, 2026
- DOW-UAP-D177 — Unresolved UAP Report, Catalina Island, 1955